Place of Origin: | Made In China |
---|---|
Brand Name: | New-Era |
Certification: | ISO9001 TS16949 |
Model Number: | ASTM B111 C12200 |
Minimum Order Quantity: | 1000kg |
Packaging Details: | bundles packing;wooden box packing |
Delivery Time: | 20days |
Payment Terms: | L/C, T/T, D/P |
Supply Ability: | 1000tons per month |
Standard:: | ASTM B111 C12200 | Material:: | C12000 C12200 C23000 C44300 C60800 C68700 C70600 C71500 |
---|---|---|---|
Shaped Tubes: | Round | Application:: | Air Condition Or Refrigerator, Water Tube, Water Heater, Oil Cooler Pipe, Water-Hezting |
Temperature Classification:: | High Temperature Piping | Customized:: | Accept |
Color:: | Red | Process:: | Drawn |
Origin:: | ZheJiang China | Package:: | Wooden Case |
Highlight: | C12000 Copper Alloy Tube,C12000 Tube,ASTM B111 Copper Alloy Tube |
Surface Condencers Red Precision Copper Pipes C12000
ASTM B111/B111M
For alloys in which copper is listed as"remainder",copper is the difference between the sum results of all the
elements determined and 100%,When all elements in Table 1 are detemined,the sum of the results shall be
as follows:
Copper Alloy UNS No. | Copper Plus Named Elements,%min |
C60800 | 99.5 |
C61300 | 99.8 |
C61400 | 99.5 |
C70400 | 99.5 |
C70600/C70620/C71000 | 99.5 |
C71000 | 99.5 |
C71500/C71520 | 99.5 |
C71640 | 99.5 |
C72200 | 99.8 |
C23000 | 99.8 |
C28000 | 99.7 |
C44300 | 99.6 |
C44400 | 99.6 |
C44500 | 99.6 |
C68700 | 99.5 |
Temper:
1.Copper tubes shall be furnisher in the temper designations identified in Tables 2 and 3
2.Drawn tempers H55 and H80
3.Annealed temper O61
4.Drawn and stress-relieved temper HR50
5.Copper tubes for ferrule stock shall be annealed sufficiently to be fully recrystallized.
Chemmical Requirements
Copper or CopperAlloy UNS No. |
Composition,% | ||||||
Copper | Tin | Aluminum | Nickel,incl Cobalt | Lead max | Iron | Zinc | |
C12000 | 99.90min | ... | ... | ... | ... | ... | ... |
C12200 | 99.9min | ... | ... | ... | ... | ... | ... |
C23000 | 84.0-86.0 | ... | ... | ... | 0.05 | 0.05max | remainder |
C44300 | 70.0-73.0 | 0.9-1.2 | ... | ... | 0.07 | 0.06max | remainder |
C60800 | remainder | ... | 5.0-6.5 | ... | 0.1 | 0.10max | ... |
C68700 | 76.0-79.0 | ... | 1.8-2.5 | 4.8-6.2 | 0.07 | 0.06max | remainder |
C70600 | remainder | ... | ... | 9.0-11.0 | 0.05 | 1.0-1.8 | 1.0max |
C71500 | remainder | ... | ... | 29.0-33.0 | 0.05 | 0.40-1.1 | 0.50max |
Brass Pipe have strong, corrosion resistant properties, and become a modern contractor in all
of commodity house pipes,heating, cooling water piping installation of choice.Widely used for
air-conditioning and refrigeration field service,heat exchange use,connecting tubes,distribution,
fire protection,solar,natural gas,liquefied petroleum gas,vent piping.
Nondestructive Testing
1.Unless nondestructive testing has been waived,Brass tubesshall be subjected to a nondestructive test.T
he manufacturer shall select the nondestructive test that is most suitable for the tube size and the application
2.Eddy-current testing is the standard nondestructivetest,andall tubes of appropriate size shall be eddy-current
tested in accordance with A
3.Tubes that are not of a size suitable for eddy-current test capabilites shall be tested by the hydrostatic test as
described in B ,or by the pneumatic test as described in C
A:Eddy Current Test-Each tube up to 3 8/1 in 【79mm】 in outside diameter shall be subjected to an eddy-current test..
B:Hydrostatic Test -When specified , the tube shall sand,without showing evidence of leakage an internal hydrostatic
pressure to subject the material to a fiber stress of 7000 psi [48MPa],determined by the following equation for thin hollow
cylinders under tension p=2Stl(D-0.8t)
C:Pneumatic Test- - -When specified, the tube shall be subjected to an internal air pressure of 60 psig [400 kPa] minimum
for 5 s without showing evidence of leakage. The test method used shall provide for easy visual detection of any leakage,
such as by immersion of the tube under water or by the pressure differential method. Any evidence of leakage shall be cause
for rejection.